Programs ported from ASO using EXP accessories do not seem to work with DriverLINX.

問題:

Programs ported from ASO using EXP accessories do not seem to work with DriverLINX.

答案:

Be sure the presence of the EXP is indicated in the DriverLINX Configuration Panel (use the button labeled as 'Special'). Relative to ASO, DriverLINX has a different channel numbering scheme, see the 'Using your hardware' manual on the DriverLINX CD. The channel numbering given in the EXP- manuals applies to ASO software only and is NOT valid with DriverLINX. For example, an EXP-1800 configured for use with DAS-board channel 0 are addressed as channels 16 - 31 under DriverLINX. Also note, DriverLINX for the DAS-1600 series does not support the use of EXP accessories directly.

此常見問答集適用於:

沒有任何產品系列

產品:

常見問答集 ID 70776