Can the minimum block sizes for the DTG Pattern Generators be worked around?

Question:

Can the minimum block sizes for the DTG Pattern Generators be worked around?

Answer:

Yes, by selecting the software sequencer mode in the Sequence menu you can get smaller minimum block sizes. There will be some imposed limitations and they are documented on page 1-85 of the DTG5078 & DTG5274 & DTG 5334 Data Timing Generator User Manual 2, P/N 071-1609-01.

This FAQ Applies to:

Product Series: DTG5000 Pulse Generator

Product: DTG5078, DTG5334

FAQ ID : 52411