Can DTG5000 single-ended outputs be used as differential?

問題:

Can DTG5000 single-ended outputs be used as differential?

答案:

Yes. There is a provision in the DTGoperating software to select "differential timing offset" which inverts the waveform on the adjacent channels to provide a complement. Then the skew between the two channels can be adjusted. This can be done for any of the channels, DTGM10, DTGM20 and DTGM21.